Application:
The products are mainly used for emergency power off of DC power supply systems such as battery cars, electric forklifts, electric vehicles.
Order notice:
For example: ZJK250A
Emergency power off switch with Rated voltage or not
Basic Technical Parameters (at normal conditions) | |||
Electric Parameters | |||
Contact type | One pair of bridge type | Instantaneous maxi (closing) current | 1000A, ≤1s |
Rated voltage of contacts (DC) | ≤80V | Insulation resistance(MΩ) | DC500V, ≥100 |
Rated current of contacts (A) | 250 | Dielectric withstand voltage | 1500V,p.f. 1min, no breakdown |
Voltage drop on contacts(mV) | ≤80 (at 100A) | Electric cycles (≥20000) | ≥1 |
Operational form | Manual | Mechanical cycles (≥300000) | ≥2 |
Disconnect thrust F1(N) | 20.0≤F1≤30.0 | Temperature rise on outgoing terminal | ≤65 |
Closed pull force F2(N) | 20.0≤F2≤40.0 | Material of contact | AgCuO(10)/Cu |
Normal closing time (ms) | ≤100 | Working duty | Continuous operating duty |
Normal disconnection time (ms) | ≤50 | ||
Mechanical/Ambient Conditions | |||
Torque of outgoing terminal on contact M8(N.m) | ≯8.5N appropriate | Protection grade | IP50 |
Torque of outgoing terminal on coil M5(N.m) | ≯2.0N appropriate | Mounting methods | Freely |
Working temperature | (-25~+55)°C | Vibration | Sine shock: 2.5g, (5~50) Hz |
Mounting altitude | ≤2Km | Impact | 50g,11ms(Half sine) |
Safety certification Quality certification | |||
3C | 2015170302000405 | GB/T19001-2008/ISO9001-2008 | QWZ19140757 |
ISO/TS16949-2009 | CNTS016227 |